hydraulic

Flood control of the Bisagno river and of the Fereggiano, Rovare and Noce streams (Italy)

Hydraulics River regulation and water resource management

Flood control of the Bisagno river and of the Fereggiano, Rovare and Noce streams (Italy)

Studies conducted by the River Basin Authority, developed within the Basin Master Plan, underlined the risk of flooding of Genoa by the Bisagno river and the Fereggiano, Rovare and Noce streams. Such risk derives from the strong difference between the capacity of the river itself and the peak discharge with a return period of 200 years.

The project foresees a series of works due to reduce the risk of flood of huge urban areas. In particular, these works include: 

  • Improvement of the hydraulic section located in the mouth reach, interested by a multiple barrel box culvert;
  • realization of a river diversion to reduce the peak discharges flowing in the original riverbed.

The project of the river diversion includes, for the Bisagno river, the following works: 

  • a river barrage equipped with n. 3 radial gates;
  • a tunnel, with a horseshoe section with 9.5 m diameter, able to carry to the Tyrrhenium sea a portion of the flood discharges derived by a lateral weir; the total length of the tunnel is 6,650 m;
  • three smaller diversion structures on the streams Fereggiano, Rovare and Noce, connected to the main tunnel through three tunnels 300 m length;
  • a sea outfall structure of the main tunnel;
  • two service tunnels.

To verify the hydraulic behaviour of the main structures, a series of tests have been performed on n. 6 physical model with regards:

  • diversion structures at the Bisagno river and at the Fereggiano, Rovare and Noce streams;
  • tunnel confluence between the main tunnel and the tunnel coming from the Fereggiano stream;
  • sea outfall structure.

The physical model tests allowed the evaluation of: 

  • the behaviour of the barrage, of the radial gates and of the lateral weir at the Bisagno barrage; 
  • the wave field in front of the outfall structure and the jet stream dissipation;
  • the stability of the rock revetment at the outfall structure;
  • the hydraulic confluence between the main tunnel and the tunnel coming from the Fereggiano stream;
  • the hydraulic behaviour of the diversion structures (vortex shafts) located at the Fereggiano, Rovare and Noce streams.
show more info show less info

Client

Province of Genoa

Location

Genoa, Italy

Services

Detailed Design, EIA

Cost of works

Euro 153,427,600

bisagno-n-3-01
bisagno-n-3-02
bisagno-n-3-03
bisagno-n-3-04
bisagno-n-3-05
bisagno-n-3-06
bisagno-n-3-07
show more images show less images

Hydraulic and hydrodynamic studies

Arcé Hydroelectric Plant (Italy)

River regulation and water resource management

Barrier Against Salt-Water Intrusion at the Estuary of Adige River

River regulation and water resource management

Design of the Rehabilitation of Cumbidanovu Dam (Orgosolo)

Hydraulic and hydrodynamic studies

Hydroelectric Plant Janiski Otoke (Republika Srpska)

River regulation and water resource management

Rehabilitation of Gibbesi Dam

River regulation and water resource management

Rehabilitation of Sciaguana Dam

River regulation and water resource management

Rehabilitation of Serra del Corvo Dam

Hydraulic and hydrodynamic studies

Settimo Hydroelectric Plant (Italy)

Hydraulic and hydrodynamic studies

Valbona hydroelectric power plant reactivation (Italy)